Update 5.061 BETA FIBARO Home Center 3
In de nieuwe update voor de FIBARO Home Center 3 zijn er een hoop nieuwe functionaliteiten toegevoegd. Let op: dit betreft een BETA versie van de software, dit betekent dat de software mogelijk onbekende bugs bevat.
Changelog:
What’s new:
Alarm
Added column with alarm scene ID.
Backup
Disabling backup creation button when reached the backups limit.
Optional saving of the history content when creating backup manually.
Dashboard
Serial number displayed as a tooltip after hovering on FIBARO logo.
Exact value from the api displayed as a tooltip on device tile and on the right sidebar.
Possibility to control com.fibaro.player devices from the right sidebar.
Possibility to open video gate from the right sidebar.
Thermostat preview available from the FIBARO Home Center app.
Icons for opening and closing states of roller shutters.
Devices
Power consumption charts in device Advanced tab.
Three new icon sets for valves.
Support for Heatit Z-Smoke Detector 230V version 4.1.
Support for Heatit Z-Temp2 version 1.1.
Support for Heatit Z-TRM3 version 4.0.
Support for Sensative Strip Guard in any version.
Support for U-Fairy Valve Shut-Off Controller.
Gateway Connection
Unlocked early access feature of connecting two or more gateways:
FIBARO Home Centers 3 may be connected only to other Home Centers 3.
Slave gateway must be empty or will be restored to factory settings.
All gateways must have the same version installed.
Backing up connected gateways together using the master gateway.
Updating connected gateways one after another starting from slave gateways.
Possibility to update all gateways or master gateway only.
Possibility to restore backup for all gateways or master gateway only.
Possibility to access slave gateways via generated password.
History
Displaying events related to power consumption of devices.
Improved displaying events from FIBARO RGBW Controllers.
Notifications
Critical push notifications available as a new channel in device notifications.
Other
Beta version status displayed on the login screen and in General Settings.
Optimized services performance and events handling.
Optimized database write and read times.
Plugins
Tedee lock plugin.
Quick Apps
Buttons and sliders available as actions in block scenes.
Update
Notice of the necessary local connection to perform the update.
Redirection to current system status after starting the update.
Bug fixes:
Alarm
Possibility to add Z-Wave devices to Satel alarm zones.
Cannot add alarm zones during the First Time Installation.
Backup
Cannot migrate cloud backups from one Home Center 3 to another.
Incorrect states when creating backups.
Cancellation of downloading an update stops creating/restoring the backup.
Cameras
No pause button on camera image preview.
Complex stream paths are improperly translated.
Devices
Temperature setpoint chart is displayed incorrectly.
Energy data on device Advanced tab is not cleared.
No possibility to add FIBARO RGBW 2 (FGRGBW-442) in security mode.
History
Incorrect units for events from multilevel sensors.
Filtering events by rooms does not work properly.
Network
Services do not start if there is a network connection without the Internet.
Notifications
Critical push notifications are not sent.
No notifications from BiDi Z-Wave device after rebooting the gateway.
Other
Chinese language version choice is not saved.
Services do not start after leaving the stand-by mode.
Power diode is not lit after leaving the stand-by mode.
Plugins
Planika fireplace plugin status is refreshed too often and results in mobile app crash.
Profiles
Scene in which the active profile is a condition does not start after rebooting.
Quick Apps
Non-admin users get the login screen when opening the quick app on the mobile app.
Non-admin users get only the custom part of quick app on the mobile app.
The first letter in labels is automatically changed to a capital letter.
No button for removing the device after leaving the edit mode.
No family section in general device settings.
Recovery
Large systems in some cases start up in recovery mode.
Scenes
Scene Activation IDs are not displayed when creating block scene.
Deactivation of a running scene does not stop the scene.
Soft reconfiguration of the device is required to run scenes with Access Control Events.
No protection against running the same scene at short time intervals.